Manufacturer Part Number
MAX306CPI
Manufacturer
Analog Devices
Introduction
MAX306CPI is a high-performance 16:1 multiplexer/demultiplexer component designed for analog signals handling, suitable for tight packaging configurations with its through-hole mounting design.
Product Features and Performance
Single multiplexer/demultiplexer circuit with a 16:1 configuration
On-State Resistance (Max): 100 Ohm
Channel-to-Channel Matching (ΔRon): 1.5 Ohm
Voltage Supply Range: Single (5V ~ 30V), Dual (±4.5V ~ 20V)
Max Switch Time (Ton, Toff): 200ns, 150ns
Charge Injection: 2pC
Channel Capacitance (CS(off), CD(off)): 8pF, 130pF
Leakage Current (IS(off) Max): 500pA
Crosstalk: -92dB at 100kHz
Operating Temperature Range: 0°C ~ 70°C
Product Advantages
High accuracy due to low channel-to-channel mismatch
Versatile supply voltage options for varied requirements
Minimized signal distortion with ultra-low crosstalk and charge injection
Key Technical Parameters
Voltage Supply, Single/Dual
Switch Time (Ton, Toff)
Crosstalk Level
Channel Capacitance
Leakage Current Specification
Quality and Safety Features
Low leakage current enhances signal integrity and overall component reliability
Meets industry standards for operating temperature and electrical parameters
Compatibility
Compatible with various analog devices requiring precision signal routing
Suitable for interfacing with digital controllers due to its digital control logic
Application Areas
Audio and Video switching
Data acquisition systems
Communication systems
Analog signal routing
Product Lifecycle
Status: Obsolete
Replacements or upgrades may be limited; verify availability of similar parts from Analog Devices or alternative manufacturers
Several Key Reasons to Choose This Product
Highly precise multiplexing capability with low resistance and near-perfect channel matching
Support for a wide range of supply voltages enhancing adaptability across different systems
Suitable for applications requiring minimal interference due to low crosstalk and leakage
Durable and reliable for industrial temperature conditions